Installation Guide
Tools Needed:
- 4-in-1 screwdriver
- Nut driver set
- Multimeter
- Pliers
- Level
- Gas leak detector (for gas models)
Step-by-Step Installation
- Choose Installation Location: Select a well-ventilated area with proper clearance from walls and combustible materials.
- Specifications
- Key Features
- Troubleshooting
- Manual Downloads
Installation Guide
Tools Needed:
- 4-in-1 screwdriver
- Nut driver set
- Multimeter
- Pliers
- Level
- Gas leak detector (for gas models)
Step-by-Step Installation
- Choose Installation Location: Select a well-ventilated area with proper clearance from walls and combustible materials.
- Remove Shipping Materials: Remove all shipping bolts, brackets, and packaging materials from the dryer.
- Electrical Connection: Connect to a properly grounded 240V outlet for electric models. Ensure proper circuit breaker rating.
- Gas Connection (Gas Models): Connect gas supply line using approved connectors. Check for leaks with detector solution.
- Ventilation System: Install rigid metal ducting with minimal bends. Ensure proper exterior vent installation.
- Level the Dryer: Adjust the leveling legs to ensure the dryer is level from front to back and side to side.
- Test Run: Run the dryer through a complete cycle to check for proper operation, heating, and ventilation.
Specifications
| Model Series | WED9500VW, WGD9500VW |
| Type | Electric & Gas Dryer |
| Color | White / Stainless Steel |
| Capacity | 9.0 cu. ft. |
| Noise Level | 58 dB |
| Control Type | Electronic Touch Controls |
| Energy Rating | ENERGY STAR® Certified |
| Power Requirements (Electric) | 240V, 60Hz, 30A |
| Gas Requirements | Natural Gas or LP (conversion kit required) |
| Dimensions (HxWxD) | 76 x 69 x 76 cm |
| Weight | 75 kg |
| Vent Requirements | 4-inch diameter rigid metal duct |
Warranty Information
- Full Warranty: 1 year parts and labor
- Motor Warranty: 10 years on dryer motor
- Additional Coverage: Optional extended warranty available
For warranty service, contact Whirlpool Customer Service at 1-800-253-1301 or visit Whirlpool.com
Key Features
Advanced Moisture Sensing
Automatically detects moisture levels and adjusts drying time accordingly, preventing over-drying and saving energy.
Wrinkle Shield™ Option
Periodically tumbles clothes without heat after cycle completion to help prevent wrinkles from setting in.
AccuDry™ Technology
Monitors temperature and moisture to deliver consistent drying results while protecting fabrics from heat damage.
Steam Refresh Cycle
Uses steam to reduce wrinkles and odors in 20 minutes, refreshing clothes without a full wash cycle.
Large Capacity Drum
9.0 cubic foot capacity accommodates large family loads, including bulky items like comforters and pillows.
Quiet Operation
Sound insulation and precision engineering provide quiet operation even with large, heavy loads.
Drying Cycles Explained
Auto Dry
Automatically senses moisture and adjusts drying time for optimal results
Timed Dry
Manual drying with user-selected time from 10 to 180 minutes
Quick Dry
Rapid drying cycle for small loads in 30 minutes or less
Steam Refresh
Reduces wrinkles and odors using steam in just 20 minutes
Heavy Duty
Extended drying time with high heat for heavily soiled items
Delicates
Gentle drying with low heat for delicate fabrics and special care items
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Dryer won't start | Power issue, door not closed, start button not pressed | Check power supply, ensure door is latched, press and hold start button |
| No heat | Heating element failure, thermal fuse, gas valve issue | Check heating element, test thermal fuse, verify gas supply (gas models) |
| Clothes not drying | Overloading, lint buildup, improper ventilation | Reduce load size, clean lint filter, check vent system |
| Excessive noise | Foreign objects, worn rollers, blower wheel issues | Check for objects, inspect rollers and blower wheel |
| Error codes displayed | Sensor failure, control board issues | Diagnose error code, check sensors and control board |
| Vibration during operation | Unbalanced load, uneven floor, worn suspension | Redistribute load, level the dryer, check suspension system |
Error Codes
- F01: Control failure - Check main control board
- F02: Thermistor open - Check temperature sensor
- F03: Thermistor short - Replace temperature sensor
- F05: Motor triac - Check motor control circuit
- F07: Heater relay - Check heating element relay
- F09: Moisture sensor - Clean or replace moisture sensor
- F11: Motor stalled - Check for obstruction or motor failure
- F13: Thermal cutoff - Check high limit thermostat
Manual Downloads
Current Model Manuals
WED9500VW
9.0 cu. ft. Electric Dryer
WGD9500VW
9.0 cu. ft. Gas Dryer
WED9620HW
9.0 cu. ft. Electric with Steam
WGD9620HW
9.0 cu. ft. Gas with Steam
Popular Previous Models
WED9200SQ
8.8 cu. ft. Electric Dryer
WGD9200SQ
8.8 cu. ft. Gas Dryer
WED8500DC
8.3 cu. ft. Electric Dryer
WGD8500DC